OAFE-1550 Outdoor Airflow Measurement System
 
 
The OAFE-1550 is an AMCA certified outdoor airflow measurement system capable of producing an overall ±0.5% accuracy through the velocity range of 200 to 1,200 fpm. The airflow measurement system consists of an integral signal processor and multipleairflow elements, factory mounted and pre-piped in a casing designed for flanged connection to ductwork, control dampers, louvers, etc. An optional inlet bell is available for plenum applications. The signal processor accepts a temperature input signal for air density compensation for standard (scfm) or actual (acfm) airflow calculations.
 

Device monitoring and configuration can also be performed by a building management system through either a LonWorks®, BACnet-MS/TP® Master or Modbus® RTU Slave communication network.  An optional controller is available that utilizes a proprietary algorithm which results in true three mode control incorporating proportional band, integral (reset) and inverse derivative (P, I, 1/D) controller functionality and tuning. The controller will provide responsive modulation of a control damper or variable speed drive guaranteeing that a constant airflow is maintained. An economizer override option is available that allows the building management system to override the minimum outdoor airflow rate.

b2
b2
b2
 
 
 
FE-1050 Fan Inlet Airflow Sensing Elements
 
 
The FE-1050 is an airflow measuring element assembly specifically designed for installation in the inlet cone of centrifugal fans or inlet bell of vane-axial fans. The design of these primary elements provides a means of accurate measurement of fan capacity along with ease of installation. Each assembly is complete with two airflow measuring elements and pivot mounting hardware. Flow transducers are sold separately.
b2
b2
 
 
 
FE-1000 Duct Insertion Airflow Sensing Elements
 
 
The FE-1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing ductwork. Where multiple elements are required for proper duct traversing, the output ports are manifolded together, external to the ductwork. Flow transducers are sold separately.
b2
b2
 
 
 
FE-1500 Duct Mounted Airflow Measurement Stations
 
 
The FE-1500 airflow measurement station consists of single or multiple airflow elements, factory mounted and pre-piped in a casing designed for flanged connection to the ductwork. Standard materials consist of a G90 galvanized casing and 6063-T5 anodized aluminum flow sensors, suitable for most HVAC applications. Flow transducers are sold separately.
b2
 
 
 
FE-1500-FX Duct Mounted Airflow Measurement Station with Straightener
 
 
The FE-1500-FX airflow measurement station has been developed for use in duct systems having a highly turbulent condition at the point of measurement. The FE-1500-FX consists of single or multiple airflow elements factory mounted and pre-piped in a casing designed for flanged connection to the ductwork and incorporates an airflow straightening section using honeycomb having a ½ inch opening by 3 inch depth. Standard materials consist of a G90 galvanized casing, 6063-T5 anodized aluminum flow sensors, and 3003 aluminum airflow straightener. Flow transducers are sold separately.